To obtain a sufficient suppleness allowing the captor deformation, it is necessary to dispose of a connection between the vessel and the pipe, at least equal to 10 times the diameter of the connection pipe ( For example, 1500 mm for a connection pipe diameter of 150 mm ).

 

 

Each weight controller is supplied with raises ( Please take into consideration this increase of height for the connection of the vessel with the pipeline ).

The voltage ( alternating ) 85 to 250 volts.

Option : 10 to 30 Volts ( direct current ) or 24 volts ( alternating )

  • Front IP 65 .
  • Precision 0,02 % .
  • Temperature from 0 to 45°C .
  • Humidity up to 95 % .
  • Electrical alimentation 85 à 250 VAC, 50/60 Hz

OPTIONS

  • a 2 alarms card - Relay 5 A/240 VAC .
  • a 4 alarms card - Relay 3 A/240 VAC .
  • Analogic outlet - Relay 4-20 mA .
  • Electrical alimentation low voltage 10 to 30 VCC or 24 VAC

  • Display range : higher and lower value, decimal separator, counter.
  • Programmation of the thresholds : -19999/+999999 .
  • Thresholds visualisation : thresholds n°1, thresholds n°2, thresholds n°3, thresholds n°4.
  • Linearity : automatic with 16 reference points.

The captor programming is done in our factory, according with your communicated data.

  • Capacity of the vessel.
  • Weight of the vessel without water.
  • Values of the different thresholds

A technical booklet is provided with each equipment.

 

PLEASE CONSULT US, OUR STUDIES ARE FREE OF CHARGE